robust-standard-detail-fft-3

pdf Download the datasheet (JCW50C) FFT-3 Treatment for E-FC-1, E-FC-2, E-FC-7 & E-FS-1

Robust FFT-3 standard batten system

Robust Detail FFT-3 resilient composite battens systems can be used in E-FC-1, E-FC-2, E-FC-7, E-FS-1, separating floors.

The acoustic battens must achieve a minimum laboratory performance of rd∆Lw=17dB.

Resilient battens must have a continuous pre-bonded layer with a minimum height of 45mm.

One advantage of Robust Detail FFT-3 Resilient Composite Batten systems is that services can be installed between battens. However they must not bridge the resilient layer on the battens.

Robust Detail FFT-3 resilient composite battens must be overlaid with an 18mm (min) tongued and grooved board. This is usually chipboard but can be plywood or engineered hardwood flooring.

A 5mm (min) resilient flanking strips is required around the perimeter of the flooring board to isolate the floating floor from walls and skirting.

It is important that the manufacturers’ recommendations are adhered to for batten centres. Please contact us for further advice on 01204 387 029.

As with any robust detail the correct external wall, separating wall internal wall and ceiling detail must be adhered to. The Robust Detail handbook should be consulted to ensure that the separating wall is compatible with the separating floor and vice versa. The Robust Detail checklist should be used to ensure that details are adhered to throughout each sequence of the build.

All acoustic battens used by JCW Acoustic Flooring have been tested in a UKAS accredited laboratory.

When installed correctly robust details should exceed the requirements set out in Part E of the Building Regulations.

With over 10 years of experience in installing all types of Robust Detail flooring solutions, JCW Acoustic Flooring have the knowledge and expertise to ensure that floating floors are installed correctly giving complete peace of mind.